Cable Type | Cable Group | Impedance | Jacket O/D mm | Dielectric Material | Dielectric O/D mm | Centre Conductor Material | Centre Conductor O/D mm | Centre Conductor Stranding mm | Shielding Outer Conductor | hf:att:pa_cable-group |
---|---|---|---|---|---|---|---|---|---|---|
Belcom EventSeries HD600 LSZH FireFighter | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.65 | 1/0.65 | Foil and Braid | fa |
Belden 1855ENH | FA | 75 | 4.45 | PEF | 2.8 | TC | 0.6 | 1/0.6 | Foil and Braid | fa |
Belden 4855ELW | FA | 75 | 4.47 | Foam | 2.89 | SCSC | 0.66 | 1/0.66 | Foil and Braid | fa |
Belden 70080NH | FA | 75 | 4.45 | PEF | 2.9 | BC | 0.65 | 1/0.65 | Foil and Braid | fa |
Belden H123A02 | FA | 75 | 4.3 | PEF | 2.9 | CU | 0.65 | 1/0.65 | Foil and Braid | fa |
Bryant BD SD01 | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.6 | 1/0.6 | Foil and Braid | fa |
Canford SDV | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.6 | 1/0.60 | Foil and Braid | fa |
Canford SDV-LFH | FA | 75 | 4.6 | PEF | 2.8 | BC | 0.6 | 1/0.60 | Foil and Braid | fa |
Canford SDV-X-LFH | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.64 | 1/0.64 | Foil and Braid | fa |
Conducfil 9890 | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.6 | 1/0.60 | Foil and Braid | fa |
Draka 0.6/2.8AF | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.6 | 1/0.6 | Foil and Braid | fa |
Draka HD PRO 0.6/2.8AF | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.6 | 1/0.6 | Foil and Braid | fa |
Image 360 | FA | 75 | 4.6 | PEF | 2.95 | BC | 0.6 | 1/0.6 | Foil and Braid | fa |
Percon VK4 | FA | 75 | 4.4 | PEF | 2.6 | BC | 0.57 | 1/0.57 | Foil and Braid | fa |
Percon VK5 | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.57 | 1/0.57 | Foil and Braid | fa |
Percon VK50 Silver+ | FA | 75 | 4.5 | PEF | SC | 0.57 | 1/0.57 | Foil and Braid | fa | |
TACHII TCX-2.8CHD | FA | 75 | 4.4 | PEF | 2.7 | BC | 0.6 | 1/0.6 | Foil and Braid | fa |
Van Damme SDI Vision | FA | 75 | 4.5 | PEF | 2.8 | BC | 0.6 | 1/0.6 | Foil and Braid | fa |
A/F Hex | Across Flats Hexagon |
AC | Alternating Current |
Al | Aluminium |
AWG | American Wire Gauge |
BC | Bare Copper |
BCCAl | Bare Copper Clad Aluminium |
BeCu | Beryllium Copper |
BCCS | Bare Copper Clad Steel |
BPS | Bits Per Second |
CCA | Copper Clad Aluminium |
CCS | Copper Clad Steel |
CPVC | Chlorinated Polyvinylchloride |
dB | Decibel |
DC | Direct Current |
DoD | Dimension over Dielectric |
EMC | Electromagnetic compatibility |
EMF | Electromotive force |
EMI | Ectromagnetic interference |
FEP | Fluorinated ethylene propylene |
FHPE | Foamed high density polyethylene |
FRPE | Fire retardant polyethylene |
g | Gram |
GHz | Giga Hertz |
GW | Galvanised wire |
HDP | High density polyethylene |
HDPE | High density polyethylene |
HF | High Frequency |
Hz | Hertz |
IP | Ingress protection |
IPE | Irradiated polyethylene tape. |
kHz | Kilohertz |
kV | Kilovolt |
LDPE | Low density polyethylene |
mA | Milli ampere |
Max | Maximum |
Mbps | Megabits per second |
MHz | Megahertz |
Min | Minimum |
mm | Millimetre |
MW | Megawatt |
N/A | Not applicable |
NCC | Nickle clad copper |
PE | Polyethylene |
PEF | Polyethylene Foam |
PPE | Polypropylene ethylene |
PTFE | Polytetrafluoroethylene |
PVC | Polyvinylchloride |
RF | Radio frequency |
RFI | Radio frequency interference. |
RMS | Root Mean Square |
SC | Silver Covered Copper |
SCC | Silver Covered Copper |
SCCA | Silver-covered copper-clad aluminum |
SCCAl | Silver-covered copper-clad aluminum |
SCCS | Silvered Covered Copper Clad Steel |
SCS | Silver-covered copper-clad steel |
SPC | Silver Plated Copper |
SPC | Silver Plated Copper |
T/P | Twisted Pair |
TC | Tinned Copper |
TCCS | Tinned copper-clad steel |
TFE | Tetrafluoroethylene |
TPE | Thermoplastic elastomer |
UL | Underwriters Laboratories |
UTP | Unshielded twisted pair |
UV | Ultraviolet |
V | Volts |
Veff | Effective voltage |
VHF | Very High Frequncy |
VSWR | Voltage Standing Wave Ratio |
μm | Micron |